DynaCHARGE™

Particulate Measurement Comparison

Continuous particulate flow/emissions monitors, filter leak analyzers, and filter leak detectors employ reliable DynaCHARGE™ induction-sensing technology.


 

Key Features


PM 100 PRO

PM 100

PM 1 PRO

PM 1

U3600-QAL
= Best          = Good          = Basic
Functions/# of Monitoring Points Multi-function/Multi-point Multi-function/Multi-point Single-function/Single-point Single-function/Single-point   Single-function/Single-point
Number of Points
(limited by type)
1 to 32 2 1 to 16 2 1 1 1
Modular Expandable System (MICS)
Resolution/Minimum Detection <1 mg/m3 ~0.1-1.0 mg/m3 1 mg/m3 ~0.1-1.0 mg/m3 0-15 mg/m3
Device Health Diagnostics
Meets EPA Performance Standards
Data Logging
On Screen Trending
Communications Fieldbus3 Fieldbus3 HART Modbus TCP Option
Alarm Capabilities
Auxiliary Inputs
(pressure, temp, flow, etc.)
Advanced Functions
(process run input, realtime & avg outputs, calculated values)

Application


PM 100 PRO

PM 100

PM 1 PRO

PM 1

U3600-QAL
= Best          = Good          = Basic
Measure (mg/m3) - Process/EPA
Monitor - Process/EPA
Detect - Maintenance
Large Stack
Multi-Compartment Baghouse
Single-Compartment Process Baghouse
Nuisance Dust Collector
Process Flow/Injection Lines/Cyclones
Other; Mist Eliminator/ESP

General Technical


PM 100 PRO

PM 100

PM 1 PRO

PM 1

U3600-QAL
Power Supply 100-240 VAC (or) 24 VDC 100-240 VAC (or) 24 VDC 2-wire loop or universal line 2-wire loop or universal line 85-260 VAC (or) 24 VDC
Processor/Display Advanced/Color Graphic Basic/Graphic Advanced/Graphic Basic LCD Basic/Graphic
Discrete Output Up to 16 Up to 8 Up to 2 Up to 2 Up to 2
Analog Output Up to 16 Up to 8 Up to 1 Up to 1 Up to 1
Analog & Discrete Inputs Up to 16 each Up to 4 each None None None
Ambient Temperature -40°F to 158°F
(-40°C to 70°C)
-13°F to 140°F
(-25°C to 60°C)
-40°F to 158°F
(-40°C to 70°C)
-13°F to 140°F
(-25°C to 60°C)
-4°F to 122°F
(-20°C to 50°C)
Particulate Sensor Type PS 10-HP or XD PS 10-S PS 10-HP or XD PS 10-S PS 10-HP or S or XD
Process Temperature
(sensor)
-40°F to 1650°F
(-40°C to 898°C)
-13°F to 450°F
(-25°C to 232°C)
-40°F to 1650°F
(-40°C to 898°C)
-13°F to 450°F (-25°C to 232°C) -40°F to 185°F
(-40°C to 85°C)
Process Pressure
(sensor)
1,000 PSI (69 bar) 10 PSI (0.69 bar) 1,000 PSI (69 bar) 10 PSI (0.69 bar)
Enclosure Rating
(explosion proof available)
NEMA 4X/IP66 NEMA 4/IP65 NEMA 4X/IP66 NEMA 4/IP65 NEMA 4X/IP66
Hazardous Area Rating Class I Div. I
(Zone 0/20)
Class II Div. II
(Zone 22)
Class I Div. I
(Zone 0/20)
Class II Div. II
(Zone 22)