Particulate Sensors
Exclusively offered in combination with an electronic unit: DynaCHARGE™ and/or B-PAC™
Free of Electronics
Accuracy and sensor life span is less effected by heat and vibration.
Hazardous Area Approvals
Make for more accessible installations since many filtration monitoring points.
PS 10 – S
This standard sensor is designed for easy install and reduced maintenance requirements.
PS 10 – HP
This high-performance sensor designed for industrial applications with a wide variety of mount and sensor configurations to meet your process requirements.
PS 10 – XD
This extreme duty sensor for challenging process applications with high temperature and pressure requirements.
PS Series Comparison
Key Features
PS 10 - S |
PS 10 - HP |
PS 10 - XD |
|
---|---|---|---|
Fully-Insulated/Isolated Probe | Coating | Layer | Layer |
Heavy Duty Construction | |||
Modular Design | |||
Rotatable Housing | |||
Field Serviceable Parts |
Application
PS 10 - S |
PS 10 - HP |
PS 10 - XD |
|
---|---|---|---|
Icon Guide : = Best = Good = Basic | |||
Aggressive/Corrosive Media | |||
Moist/Conductive Media |
General Technical
PS 10 - S |
PS 10 - HP |
PS 10 - XD |
|
---|---|---|---|
Process Connection | NPT, Quick Clamp | NPT, Quick Clamp, Flange | |
Wetted Materials |
316 L Teflon - |
316 L Hastelloy C Teflon |
316 L Hastelloy C Teflon |
Max. Process Temperature |
450°F (232°C) |
500°F (260°C) |
1650°F (898°C) |
Max. Process Pressure | 10 PSI (0.69 bar) | 100 PSI (6.9 bar) | 1000 PSI (69 bar) |
Max. Probe Length | 36 in (914 mm) | 72 in (1828 mm) | 36 in (914 mm) |
Enclosure Rating (explosion proof available) | NEMA 4X/IP66 | NEMA 4X/IP66 | NEMA 4X/IP66 |
Hazardous Area Rating | Class II Div. II (Zone 22) | Class I Div. I (Zone 0/22) | Class I Div. I (Zone 0/22) |
If you require a sensor tailored to your specific needs, our Auxiliary Sensors are designed to meet any application. To begin, just complete our Application Review Form or get in touch with one of our experts for further details.