Advanced Baghouse Performance Analysis & Control

B-PAC™ Comparison

 

B-PAC™ Control and monitoring systems for all types of baghouses and cartridge dust collectors provide optimized filtration and highly beneficial preventive diagnostics.


 

Key Features


B-PAC™ G3 PRO

B-PAC™ G3

B-PAC™ PRO ES
= Best          = Good          = Basic
Expandable Modular Platform (MICS™)
Distributed Enclosures Single Enclosure Only
Filter Type
Max. # of Compartments
Max. # of Filter Rows
Max # of Header Tanks
All
8
256
8
Pulse Jet Only
2
96
4
All
No limit
No Limit
No Limit
IntelliPULSE™ DP Control
Filter Leakage by Row
Solenoid Condition by Row
Diaphragm Condition by Row
On-line Cleaning
Off -line Cleaning
DP Control (flange to flange)
DP Control (by compartment)
On-Screen Trending
Alarm Capabilities
Data Logging
Device Health Diagnostics
Aux. Monitoring (temperature, flow, level, etc.)
Aux. Control (dampers, screw conveyors, fans, etc.)

Application


B-PAC™ G3 PRO

B-PAC™ G3

B-PAC™ PRO ES
= Best          = Good          = Basic
Single-Compartment Baghouses
Mutli-Compartment Baghouses
Nuisance Dust Collector(s)
EPA Compliance

General Technical


B-PAC™ G3 PRO

B-PAC™ G3

B-PAC™ PRO ES
Power Supply 100-240 VAC (or) 24 VDC 100-240 VAC (or) 24 VDC 100-240 VAC (or) 24 VDC
Processor/Display Advanced/Color Graphic Basic/Monochrome Advanced/Color Graphic
Analog & Discrete I/O Fieldbus 2 Fieldbus 2 Fieldbus 2
Communication Up to 16 each Up to 4 each None
Ambient Temperature -40°F to 158°F
(-40°C to 70°C)
-13°F to 140°F
(-25°C to 60°C)
-40°F to 158°F
(-40°C to 70°C)
Enclosure Rating
(explosion proof available)
NEMA 4X/IP66 NEMA 4/IP65 NEMA/IP as Requested
Hazardous Area Rating Class I Div. I (Zone 0/20) Class II Div. II (Zone 22) Class I Div. I (Zone 0/20)